Some devices are new, others are refurbished. All these devices are exhibited there 7 days before the date of sale, from 9 a.m. to 6 p.m. on working days and by appointment (join us +41 21 321 8000, info@swiss.auction). CAM company will directly invoice you for your purchase. The auction hammerprice corresponds to the aount you will have to pay (with or without VAT, depending on your status). There is no commission from the auction house swiss.auction . All devices sold in this auction have been tested by Seller CAM and work perfectly. An image proof is produced before collection of the goods and given to the Buyer at his request, before collection.


All the equipments presented in this private auction are stored at CAM, 252 rue de Rosny, 93100 Montreuil, FRANCE. This address is the place of collection of the goods.

למידע נוסף
המכירה הסתיימה

פריט 21:

GE AVANCE CS2 ANESTHESIA VENTILATOR. with CARESCAPE ANESTHESIA MONITORING

לקטלוג
  לפריט הקודם
לפריט הבא 
נמכר ב: €8,000
מחיר פתיחה:
3,000
הערכה :
€15,000
עמלת בית המכירות: 0% למידע נוסף
המכירה התקיימה בתאריך 30.11.23 בבית המכירות Art medical Suisse (A.M.S.) SA
תגיות:

GE AVANCE CS2 ANESTHESIA VENTILATOR. with CARESCAPE ANESTHESIA MONITORING
VENTILATOR OPERATING SPECIFICATIONS • Ventilator parameter ranges • Tidal volume range: 5 to 1500ml ( Volume Control, PCV-VG and SIMV volume 20 to 1500ml) (PCV modes 5 to 1500ml) • Incremental settings: 20 to 50 mL (increments of 1 mL) • 50 to 100 mL (increments of 5 mL) • 100 to 300 mL (increments of 10 mL) • 300 to 1000 mL (increments of 25 mL) • 1000 to 1500 mL (increments of 50 mL) • Minute volume range: Less than 0.1 to 99.9 L/min • Pressure (Pinspired) range: 5 to 60 cmH2O (increments of 1 cmH2O) 5 to 1500 mL volume delivery • Pressure (Pmax) range: 12 to 100 cmH2O (increments of 1 cmH2O) • Pressure (Psupport) range: Off, 2 to 40 cmH2O (increments of 1 cmH2O) • Rate: 4 to 100 breaths per minute for • Volume Control and Pressure • Control; 2 to 60 breaths per minute for SIMV, PSVPro and SIMV PCV-VG; 4 to 60 bpm for CPAP+PSV (increments of 1 breath per minute) • Inspiratory/ expiratory ratio: 2:1 to 1:8 (increments of 0.5) • Inspiratory time: 0.2 to 5.0 seconds (increments of 0.1 seconds) (SIMV, PSVPro and CPAP PSV) • Trigger window: 0 to 80% (increments of 5%) • Flow trigger: 1 to 10 L/min (increments of 0.5 L/min) • 0.2 to 1 L/min (increments of 0.2 L/min) • Inspiration • termination level: 5 to 75% (increments of 5%) • Inspiratory Pause range: 0-60% • Positive End Expiratory Pressure (PEEP) • Type: Integrated, electronically • controlled • Range: OFF, 4 to 30 cmH2O (increments of 1 cmH2O) • Ventilator performance • Pressure range at inlet: 240 kPa to 700 kPa (35 psig to 100 psig) • Peak gas flow: 120 L/min + fresh gas flow • Flow valve range: 1 to 120 L/min • Flow compensation range: 150 mL/min to 15 L/min • Ventilator Accuracy • Delivery/monitoring accuracy • Volume delivery: > 210 mL = better than 7% • ≤ 210 mL = better than 15 mL • < 60 mL = better than 10 mL • Pressure delivery: ±10% or ±3 cmH2O • PEEP delivery: ±1.5 cmH2O • Volume monitoring: > 210 mL = better than 9% • ≤ 210 mL = better than 18 mL • < 60 mL = better than 10 mL • Pressure monitoring: ±5% or ±2 cmH2O • ALARM SETTINGS • Tidal volume (VTE): Low: OFF, 1 to 1500 mL • High: 20 to 1600 mL, OFF • Minute volume (VE): Low: OFF, 0.1 to 10 L/min • High: 0.5 to 30 L/min, OFF • Inspired oxygen (FiO2): Low: 18 to 99% • High: 19 to 100%, OFF • Apnea alarm: Mechanical ventilation ON: • < 5 mL breath measured in 30 seconds • Mechanical ventilation OFF: • < 5 mL breath measured in 30 seconds • Low airway pressure: 4 cmH2O above PEEP • High pressure: 12 to 100 cmH2O (increments of 1 cmH2O) • Sustained airway pressure: Mechanical ventilation ON: • Pmax < 30 cmH2O, the sustained limit is 6 cmH2O • Pmax 30 to 60 cmH2O, the sustained limit is 20% of Pmax • Pmax > 60 cmH2O, the sustained limit is 12 cmH2O • PEEP and mechanical ventilation ON • Sustained limit increases by PEEP minus 2 cmH2O • Mechanical ventilation OFF: • Pmax ≤ 60 cmH2O, the sustained limit is 50% of Pmax • Pmax > 60 cmH2O, the sustained limit is 30 cmH2O • Subatmospheric pressure: Paw < -10 cmH2O • Audio pause countdown clock: 120 to 0 seconds • Ventilator Components Flow transducer • Type: Variable orifice flow sensor • Dimensions: 22 mm OD and 15 mm ID • Location: Inspiratory outlet and expiratory inlet • Ventilator screen • Display size: 15 inch • Pixel format: 1024 x 768 • Battery backup • Backup power: Demonstrated battery time is up to 90 minutes when fully charged. • Battery time under extreme conditions is 30 minutes. • Battery type: Internal rechargeable sealed lead acid • Communication ports • RS-232C compatible serial interface • Ethernet • Datex-Ohmeda device interface solutions port • USB port • VGA Output • Anesthetic Agent Delivery • Delivery Vaporizers: Tec* 6 Plus, Tec 7 • Number of positions: 2 (3 as an option) • Mounting: Tool-free installation Selectatec* manifold interlocks and isolates vaporizers • Airway Modules • General • M-CAiO, M-CAiOV, M-CAiOVX module software • version 3.2 or higher; E-CAiO, ECAiOV, E-CAiOVX • • Size (WxDxH): 75 x 228 x 112 mm/ 3.0 x 9.0 x 4.4 in • Weight: 1.6 kg/3.5 lb • Sampling rate: 200 mL/min ±20 mL E-sCAiO, E-sCAiOV • Size (WxDxH): 38 x 205 x 113 mm/1.5 x 8.1 x 4.4 in • Weight: 0.7 kg/1.5 lb • Sampling rate: 120 mL/min ±20 mL • Automatic compensation for atmospheric pressure variation (500 to 800 mmHg for E-, M-series modules; 495 to 795mmHg for CARESCAPE modules) temperature and CO2/N2O and CO2/O2 collision broadening effect. Parameter display update interval typically breath-by-breath. Functional alarms for blocked sample line, D-fend check and D-fend replacement. • Non-disturbing gases: • Ethanol, acetone, methane, nitrogen, nitric oxide, carbon monoxide, water vapor: • Maximum effect on readings: CO2 < 0.2 vol %; O2, N2O < 2 vol % • Carbon dioxide (CO2) • EtCO2: End-tidal CO2 concentration • FiCO2: Inspired CO2 concentration • CO2 waveform • Measurement range: 0 to 15% (0 to 15 kPa, 0 to 113 mmHg) • Accuracy: ±0.2 vol % + 2 % of reading • Datex-Ohmeda infrared sensor • Adjustable low and high alarm limits for EtCO2 and FiCO2 • Respiration rate (RR) • Measurement range: 4 to 60 breaths/min for E-, M-series modules 4 to 100 breaths/min for CARESCAPE modules • Detection criteria: 1% variation in CO2 • Adjustable low and high alarm limits for respiration rate; alarm for apnea • Patient Oxygen (O2) • FiO2: Inspired O2 concentration • EtO2: End-tidal O2 concentration • FiO2-EtO2: Inspired-expired difference • O2 Measurement • Measurement range: 0 to 100% • Accuracy: ±1 vol % +2 % of reading • Datex-Ohmeda differential paramagnetic sensor • Adjustable low and high alarm limits for FiO2 and EtO2; alarm for FiO2 < 18% • Nitrous Oxide (N2O) • Measurement range: 0 to 100% • Accuracy: ±2 vol % +2 % of reading • Anesthetic Agent (AA) • Halothane, Isoflurane, Enflurane • Measurement range: 0 to 6% • Accuracy: ±(0.15 vol% +5% of reading) • SEVOFLURANE • Measurement range: 0 to 8% • Accuracy: ±(0.15 vol% +5% of reading) • Desflurane • Measurement range: 0 to 20% • Accuracy: ±(0.15 vol% +5% of reading) • Waveform displayed • MAC value displayed • Identification threshold: 0.15 vol %1 • Agent mixture detection • Adjustable high and low alarm limits for EtAA, FiAA • Patient Spirometry* • Pressure-volume loop • Pressure-flow loop • Flow-volume loop • Airway pressure and flow waveforms • Adjustable low and high alarm limits for Ppeak, PEEPtot and • MVexp • Alarms for MVexp << MVinsp and for MVexp low. Detection through D-lite* or Pedi-lite* flow sensor and gas sampler with following specifications: • Compact Airway Modules • D-lite Pedi-lite • Respiration rate: 4 to 35 4 to 50 breaths/min breaths/min • Tidal volume • Measurement range: 150 to 15 to 2000 mL 300 mL Accuracy1: ±6% or 30 mL ±6% or 4 mL • Minute volume • Measurement range: 2 to 20 L/min 0.5 to 5 L/min • Accuracy1: ±6% ±6% • Airway pressure • Measurement range: -20 to +100 cmH2O • Accuracy1: ±1 cmH2O • Display units: cmH2O, mmHg, kPa, mbar, hPa Flow • Measurement range: 1.5 to 0.25 to 25 L/min100 L/mi I:E • Measurement range: 1:4.5 to 2:1 • Compliance • Measurement range: 4 to 100 1 to 100 mL/cmH2O mL/cmH2O Airway resistance • Measurement range: 0 to 40 cmH2O/L/s • CARESCAPE Airway Modules D-lite(+) Pedi-lite(-) • Respiration rate: 4 to 35 4 to 70 breaths/min breaths/min • Tidal volume • • Measurement range: 150 to 5 to 2000 mL 300 mL • Accuracy1: ±6% or 30 mL ±6% or 4 mL • Minute volume • Measurement range: 2 to 20 L/min 0.1 to 5 L/min • Accuracy1: ±6% ±6% • Airway pressure • Measurement range: -20 to +100 cmH2O • Accuracy1: ±1 cmH2O • Display units: cmH2O, mmHg, kPa, mbar, hPa Flow • Measurement range: -100 to -25 to 25 L/min 100 L/min I:E • Measurement range: 1:4.5 to 2:1 • Compliance • Measurement range: 4 to 100 1 to 100 mL/cmH2O mL/cmH2O • Airway resistance • Measurement range: 0 to 200 cmH2O/L/s • Sensor specifications D-lite/ Pedi-lite/ • at 10 L/min: 1.0 cmH2O